Electrophoresis Buffers
Artikel-Nr:
(28-9374-52)
Lieferant:
Cytiva
Hersteller-Artikelnummer::
28-9374-52
Lokale Artikelnummer::
GEHE28-9374-52
Beschreibung:
DIGE buffer kit is a tool to increase the quality, reproducibility, and convenience of 2-D DIGE using the Ettan™ DIGE system. The DIGE buffer kit is a specially designed two-buffer system for running up to twelve DIGE gels simultaneously.
VE:
1 * 1 KIT
Artikel-Nr:
(PIER37570)
Lieferant:
Thermo Scientific
Hersteller-Artikelnummer::
37570
Lokale Artikelnummer::
PIER37570
Beschreibung:
These protein-free blocking buffers are either a PBS or a TBS formulation of a non protein compound that provides effective blocking for membrane based and plate based protein detection methods, resulting in extremely low background.
VE:
1 * 1 L
Lieferant:
G-Biosciences
Beschreibung:
FISH-Blocker™ uses a fish protein as the primary blocking agent to eliminate cross reactivity. Using a non mammalian protein eliminates or minimises the interaction of antibodies raised in mammals. It is offered either in TBS (Tris-buffered saline) or in PBS (phosphate-buffered saline) at pH 7,5.
Artikel-Nr:
(HEWLG1600-62318)
Lieferant:
Agilent
Hersteller-Artikelnummer::
G1600-62318
Lokale Artikelnummer::
HEWLG1600-62318
Beschreibung:
CEP-beschichtete Kapillaren enthalten eine dauerhaft gebundene Polymerbeschichtung. Diese CEP-Beschichtung schützt die Silanolfunktionalität der Kapillaroberfläche und hilft, eine Probenadsorption zu verhindern. Darüber hinaus wird EOF nahezu eliminiert, wodurch sich die Kapillare ideal für Anwendungen wie DNA-Trennungen mit Siebpolymerpuffern eignet.
VE:
1 * 2 ST
Artikel-Nr:
(HEWL5063-6514)
Lieferant:
Agilent
Hersteller-Artikelnummer::
5063-6514
Lokale Artikelnummer::
HEWL5063-6514
Beschreibung:
CE/MS sprayer kit and CE/MS adapter kit to couple an Agilent CE instrument with an MS system.
VE:
1 * 1 ST
Artikel-Nr:
(28-9374-51)
Lieferant:
Cytiva
Hersteller-Artikelnummer::
28-9374-51
Lokale Artikelnummer::
GEHE28-9374-51
Beschreibung:
DIGE gel is a 12,5% precast polyacrylamide gel in a low fluorescent glass cassette for second dimension 2-D electrophoresis and specially developed for 2-D DIGE analysis. DIGE gel and DIGE buffer kit are tools to increase the quality, reproducibility, and convenience of 2-D DIGE using Ettan™ DIGE system.
VE:
1 * 3 ST
Artikel-Nr:
(730-0183)
Lieferant:
THERMO OWL SCIENTIFIC
Hersteller-Artikelnummer::
B1A-BP
Lokale Artikelnummer::
OWLAB1A-BP
Beschreibung:
Das Mini-Gelsystem Owl™ B1A EasyCast™ wurde entwickelt, um flache, ebene Bandenmuster und konsistente Ergebnisse mit minimalem Aufwand zu gewährleisten. Dieses System eignet sich ideal für die Bestimmung von Molekulargewichts-Bereichen von PCR Fragmenten oder größeren DNS-Molekülen. Das kompakte Design ermöglicht das Gießen von Gelen sowie den Gellauf in der Pufferkammer; daher ist keine zusätzliche Ausstattung notwendig.
VE:
1 * 1 ST
Artikel-Nr:
(786-411)
Lieferant:
G-Biosciences
Hersteller-Artikelnummer::
786-411
Lokale Artikelnummer::
GENO786-411
Beschreibung:
Insect PE LB™ has been developed for extraction of total biologically active, soluble proteins from adherent or suspension cultured insect cells, including Sf9 and Sf21. Insect PE LB™ utilises a mild non-ionic detergent and a proprietary combination of various salts and agents to enhance extraction and stability of proteins. The Insect PE LB™ is fully compatible with downstream processes, such as electrophoresis and chromatography. Depending on the required downstream application, additional agents such as reducing agents and protease inhibitors may be added into Insect PE LB™.
VE:
1 * 250 mL
Lieferant:
MP Biomedicals
Beschreibung:
Storage: Store at Room Temperature (15-30 °C)
Glycine is a non-essential amino acid. It is only amino acid with no asymmetric carbon and thus is not chiral. It is the major inhibitory neurotransmitter. It is involved in the biosynthesis of the porphyrin rings of hemes and chlorophylls. Glycine is commonly used in buffer solutions, in electrophoresis and preparative chromatography. A study of the folding of monoclonal antibodies in the presence of glycine and their subsequent purification has been published. The use of glycine in the purification of lipopolysaccharides, lipooligosaccharides, and lipid A has been reported. It is an amino acid for use in cell culture media development applications and existing media formulations. Glycine is commonly used as a component in Tris-glycine and Tris-glycine-SDS running buffers for polyacrylamide gel electrophoresis, a component of Towbin's transfer buffer for Western blots, a buffer substance in cryoenzymology, in osmotic pressure maintenance in isoelectric focusing of erythrocytes, salting-in effect in protein chemistry, and as a buffer component in the coupled phosphatase-kinase reaction for end labelling of restriction fragments. The growth requirements of various microorganisms is reported in the Handbook of Microbiology. Glycine is a non-chiral amino acid that can be synthesized in the body from the amino acid serine by Serine Hydroxymethyltransferase. Inhibitory neurotransmitter in spinal cord, allosteric regulator of NMDA receptors.
Artikel-Nr:
(PIER37525)
Lieferant:
Thermo Scientific
Hersteller-Artikelnummer::
37525
Lokale Artikelnummer::
PIER37525
Beschreibung:
Blocker BSA in PBS or TBS are ready-to-use, 1X PBS or TBS solutions of 10X (10%) bovine serum albumin protein for blocking steps in Western blot, ELISA, IHC and nucleic acid detection methods.
VE:
1 * 200 mL
Lieferant:
MP Biomedicals
Beschreibung:
Tris has been useful as buffers in a wide variety of biological systems. Uses include pH control in vitro and in vivo for body fluids and in buffering systems for electrophoresis applications. Tris has been used as a starting material for polymers, oxazolones (with carboxylic acids) and oxazolidines (with aldehydes). Tris does not precipitate calcium salts and is of value in maintaining solubility of manganese salts. It can be used for the direct standardization of a strong acid solution; the equivalence point can be determined either potentiometrically or by use of a suitable indicator such as 3-(4-Dimethylamino-1-naphthylazo)-4-methoxybenzenesulfonic acid. It is an auxiliary material in pharmaceutical science.
Store at Room Temperature (15-30 °C). Store dessicated.
Artikel-Nr:
(PIER28348)
Lieferant:
Thermo Scientific
Hersteller-Artikelnummer::
28348
Lokale Artikelnummer::
PIER28348
Beschreibung:
Our variety of Pierce Concentrated Buffer stock solutions are ready to use without having to weigh and dissolve dry ingredients or adjust the pH with concentrated acid or base. Simply dilute the liquid stock solution with pure water and proceed with your experiment.
VE:
1 * 0,5 L
Lieferant:
MP Biomedicals
Beschreibung:
Storage: Store at Room Temperature (15 - 30 °C)
Glycerol is used both in sample preparation and gel formation for polyacrylamide gel electrophoresis. Glycerol (5-10%) increases the density of a sample so that the sample will layer at the bottom of a gel’s sample well. Glycerol is also used to aid in casting gradient gels and as a protein stabilizer and storage buffer component. Glycerol is used in the concentration and storage of enzymes. Also prevents back-diffusion and protein samples into the buffer. Ideal for use as a cryoprotectant.
Lieferant:
G-Biosciences
Beschreibung:
Die Waschpuffer femto TBST™ und PBST™ erhöhen die Empfindlichkeit von Immunassays durch Minimierung des „Auswaschens“ von Immunagenten oder Immunkomplexen, einem Problem, das häufig im Zusammenhang mit klassischen TBST- und PBST-Puffern auftritt. Die Waschpuffer unterstützen das Erstellen sauberer Hintergründe und führen damit zu einem besseren Verhältnis von Signal und Hintergrund. Sie können bei Inkubations- und Waschvorgängen verwendet werden.
Artikel-Nr:
(EKSIC44807)
Lieferant:
EKSIGENT
Hersteller-Artikelnummer::
C44807
Lokale Artikelnummer::
EKSIC44807
Beschreibung:
SCIEX Low pH SDS Sample Buffer, 140 mL (100 mM Tris-HCl, pH 6.8, 1% SDS) allows you to use SCIEX’s Gold Standard CE-SDS with a low pH SDS sample buffer. Use of this buffer can increase non-reduced purity by decreasing method induced fragmentation. Less variability and lower RSDs means less troubleshooting and faster method development.
VE:
1 * 1 ST
Lieferant:
Agilent
Beschreibung:
PVA-beschichtete Kapillaren enthalten eine permanent adsorbierte Schicht aus Polyvinylalkohol. Diese Beschichtung minimiert hydrophobe und elektrostatische Wechselwirkungen zwischen gelösten Stoffen und Wänden und eliminiert den elektroosmotischen Fluss (EOF). Durch ein proprietäres Abscheidungsverfahren ist die PVA-Beschichtung über einen weiten pH-Bereich stabil, selbst unter basischen Bedingungen von 2,5 bis 9,5. Diese Stabilität ermöglicht die Verwendung vieler gängiger CE-Puffer. Da die Kieselsäureoberfläche beschichtet ist, können viele Proteine und Amine ohne das Peak-Tailing analysiert werden, das bei unbeschichteten Kapillaren auftritt. Da zudem EOF eliminiert wird, sind umständliche Waschvorgänge unnötig und die Reproduzierbarkeit der Migrationszeit kann verbessert werden.
Preis auf Anfrage
Lager für diesen Artikel ist begrenzt, kann aber in einem Lagerhaus in Ihrer Nähe zur Verfügung. Bitte stellen Sie sicher, dass Sie in sind angemeldet auf dieser Seite, so dass verfügbare Bestand angezeigt werden können. Wenn das
![]()
Lager für diesen Artikel ist begrenzt, kann aber in einem Lagerhaus in Ihrer Nähe zur Verfügung. Bitte stellen Sie sicher, dass Sie in sind angemeldet auf dieser Seite, so dass verfügbare Bestand angezeigt werden können. Wenn das
![]()
Dieses Produkt kann nur an eine Lieferadresse versandt werden die über die entsprechende Lizenzen verfügt. Für weitere Hilfe bitte kontaktieren Sie Ihr VWR Vertriebszentrum.
-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
Dieses Produkt wurde von Ihrer Organisation gesperrt. Bitte kontaktieren Sie Ihren Einkauf für weitere Informationen.
Dieses Produkt ist Ersatz für den von Ihnen gewünschten Artikel.
Dieses Produkt ist nicht mehr verfügbar. Bitte kontaktieren Sie den VWR Kundenservice.
|
|||||||||